SL150 Installation and Setup Guide
21–2
– Hayes Smartmodem Optima 2400
– Hayes Optima 2400 Fax96
– Hayes Smartmodem 1200 External Modem
– Hayes Smartmodem 1200B Internal Modem (Rev. 1.2 or higher)
– Hayes external
Optima 24 Plus FAX96 Modem
– Practical
Peripherals PM14400FXSA
COMPASS® Downloader Software (at revision level supporting the
SL150
)
Appropriate interconnecting cables
Initial Download
For initial downloading, enter
[Installer code] + # + 5
. This sets field
95 to 4 rings, and
system to “no call-back” option. The download computer can then call the subscriber, make
the connection, and download all programming items.
After the control and the PC have established valid communication, each keypad on the
system will become inactive and will display “
CC
” or “
MODEM COMM
.” The control,
however, will still be scanning its zones and looking for alarms. If an alarm does occur, after
communication is broken off, alarms are sounded and the proper dialer reports are sent to
the Central Station. The keypads will become active after the download communication is
terminated. The detailed operation of the download functions is covered in the installation
instructions for the COMPASS Downloader.
Remote Programming Commands
The downloading system can perform many functions when in communication with the
control unit. Besides uploading and downloading, the status of the system can be observed
and various commands can be initiated, as follows:
Arm the system in the AWAY mode; disarm the system.
Bypass a zone.
Force the system to accept a new program download.
Shut down communication (dialer) functions (in response to nonpayment of monitoring fees
in an owned system).
Shut down all security system functions (in response to nonpayment for a leased system).
Inhibit local keypad programming (prevents account takeover).
Command the system to upload a copy of its resident program to the office.
Read: arming status, AC power status, lists of faulted zones, bypassed zones, zones
currently in alarm, zones currently in trouble, and RF sensors with low-battery conditions.
Note:
One of the following messages will be displayed following an upload:
Alpha Keypads Fixed-word Keypads
Upload failed dF
Upload completed dC
Remote Programming Advisory Notes
Alarm and trouble reporting may be delayed during the time that the system and the
downloader are linked to each other following a valid exchange of codes, but the proper
message will get through to the Central Station after the link is broken.
Keypad entries are ignored during the time interval stated above.
A copy of the program downloaded may be produced from the IBM PC-compatible
computer, using the product's internal report generator, when an optional printer is
connected (consult your PC manual for proper printer and connections).