SECTION 18
Zone Lists
(
81 Menu Mode)
••••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
About Zone List Menu Mode
Zone List Displays
Pager 1 Reporting - Zone List 06
Pager 2 Reporting - Zone List 07
••••••••••••••••••••••••••••••••••••••••••••••••••
About Zone List Menu Mode
Zone List Menu mode is used to program zone lists for output devices (programmed in
80
Menu mode). Refer to the Programming Form worksheet for
81 Mode. To enter Zone List
Menu mode,
press
81
while in program mode
.
Zone List Displays
Zone List No.
(00 = Quit) 01
Enter the Zone List Number (01, 02, 03, 06 or 07) that you want to
program (or 00 to end these entries).
Press
to advance.
In the following displays, zone list 01 has been selected for
programming
.
01 Enter Zn Num.
(00 = Quit) 00
Enter each zone number to add to the zone list by first entering the
zone number, then
(for example, 01
, 02
, etc.). After all zones
desired are entered, press
00
to advance.
Important:
Do not include fire zones in zone lists that are used to
STOP relay actions.
01 Del Zn List?
0 = No 1 = Yes 0
To delete the zone list, enter
1
(Yes). All zones in the zone list will be
deleted automatically and programming will return to the first
screen.
To save the zone list, enter
0
(No) to advance.
01 Delete Zone?
0 = No 1 = Yes 0
To save the entire zone list, enter
0
(No) and programming will
return to the first screen.
To delete a zone or zones in a zone list, enter
1
(Yes) to advance.
01 Zn to Delete?
(00 = Quit) 00
Enter each zone to be deleted from the list, followed by [
]. After all
zones to be deleted are entered, enter
00
to return to the first screen
so that another list can be programmed, if desired.
NOTES:
Any list may include any or all of the system's zone numbers.
A zone list can be assigned to more than one output relay.