SL150 Installation and Setup Guide
23–2
Notes:
All Master and Secondary User codes permit access to the system for arming, disarming, etc.
The Installer code can disarm the system only if it was used to arm it.
Babysitter code is User code No. 15; it can disarm the system only if that code (or the
installer code) was used to arm it.
Duress code is User code No. 16;. When this is used to perform any system operation, a
special code is sent to the monitoring station (this is a silent alarm, no sounds, no displays).
Instruct users to be careful not to use this code for normal usage.
If a Secondary User code is inadvertently repeated for different users, the lower user number
will take priority.
Opening and Closing reports are sent for the Installer code as No. 01, with the appropriate
subscriber number. Each Master code and set of Secondary User codes are sent as Nos. 02
and 03–16, respectively, in Contact ID format (with the appropriate subscriber number). In
4+2 format, it is 1–F, “F” for anything greater than 14.
Keypad Functions
Arming and Disarming
The keypad allows the user to arm and disarm the system, and to perform other system
functions, such as bypass zones and display zone descriptors. Zone and system conditions
(alarm, trouble, bypass) are displayed in the display window.
All keypads with backlighting capability will automatically illuminate when the system is
placed in entry mode.
When an alarm occurs, keypad sounding and external sounding will occur, and the zone(s) in
alarm will be displayed on the keypad. Pressing any key will silence the keypad sounder for
10 seconds. Disarming the system (code + OFF) will silence both keypad and external
sounders. When the system is disarmed, any zones that were in an alarm condition during
the armed period will be displayed. To clear this display, simply repeat the disarm sequence
(enter the security code and press the OFF key) again.
The keypads also feature chime annunciation, and 3 panic key pairs. The panic keys can be
programmed for silent, audible, fire, or personal emergencies, and will notify the central
station of the alarm condition, if that service is connected.
Arming Commands
The following is a brief list of system commands. For detailed information concerning system
functions, refer to the User Guide.
Disarmed, Not Ready
Before arming, the system must be in the “System Ready” condition (all
zones must be intact). If the
NOT READY
message appears, press
(READY
key) to display faulted zones.
Arming AWAY
........................Enter code +
2
[AWAY] key, or press the “A” key (no code entry required).
Arming STAY
.........................Enter code +
3
[STAY] key, or press the “B” key (no code entry required).
Arming INSTANT
..................Enter code +
7
[INSTANT]
key, or press the “C” key* (no code entry
required). * Unless programmed for macros operation
Disarming
...............................Enter code +
1
[OFF] key.
Bypassing Zones
....................Enter code +
6
[BYPASS] key plus zone number(s).
Forced (Quick) Bypass
.........To automatically bypass all faulted zones, use the “Quick Bypass”
(if enabled)
method: Enter code plus
6
[BYPASS], then wait for all open zones to be
displayed. You can arm when the display indicates
BYPASS
or
SYSTEM READY
.
Chime Mode
...........................
Enter
code + 9 CHIME
key.
To turn chime off, enter code + 9 CHIME
key
again.
Vista de pagina 115
1 2 ... 111 112 113 114 115 116 117 118 119 120 121 ... 143 144

Comentarios a estos manuales

Sin comentarios