Security Link SL150 Guía para resolver problemas Pagina 62

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 144
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 61
SL150 Installation and Setup Guide
13–2
Entering Program Mode
You may use one of the following methods:
a) Press [
] and [#] keys at the same time within 50 seconds after power is applied to the
control; or
b) After power-up, enter 4 1 1 2 (Installer code) + 8 0 0.
This method is disabled if you exit the Program mode using
98 instead of
99. See the
paragraph titled, Exiting the Program Mode, later in this section.
If a different Installer code is subsequently programmed, use it instead of 4112 to gain
access to the Programming mode.
When you enter the Program mode, data field
20 will be displayed (this is the first data field
in the system). The system will now accept entries for field
20.
Programming a Data Field
1. Press [
] + [Field No.] (for example,
22), then make the required entry.
2. When you have completely programmed a data field, the keypad will beep three times and
then automatically display the next data field in sequence. To go to a different field, press
[
] plus the desired field number.
3. If the number of digits that you need to enter in a data field is less than the maximum
digits available (for example, the phone number field), enter the desired data, then press
[
] and the next data field number to be programmed.
4. If you try to enter a non-existent field, the keypad will display EE or ENTRY ERROR.
Simply re-enter [
] plus a valid field number.
Reviewing a Data Field/Erasing an Entry
Press [#] + [Field No.]. Data will be displayed for that field number. No changes will be
accepted in this mode.
To delete an entry in a field, press [
] + [Field No.] + [
] (applies only to fields
40
το
44,
85, 86, 87,
88, and
94).
Interactive Mode Programming (
56,
58,
80,
81,
82)
Typical prompt displayed
during Interactive mode
programming:
Enter Zn Num.
(00 = Quit) 01
Press [
]
+
[Interactive Mode No.]
(for example,
56). The
alpha keypad will display the first of a series of prompts
requesting entries.
A detailed procedure (with displays of prompts) is provided in
later sections of this manual.
Zone Number
Interactive Mode Used to Program
56 Zone Programming
Zone characteristics, report codes,
alpha descriptors and serial numbers
58
Expert Mode
5800 Series Transmitter serial and
loop numbers
80 Relay Programming
4229 or 4204 Relay modules, or
Powerline Carrier devices
81 Zone List
Programming
Zone lists for relay/powerline carrier,
assignment of chime zones, and Pager
1 and 2 reporting zones
82 Alpha Programming
Zone alpha descriptors
Vista de pagina 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 ... 143 144

Comentarios a estos manuales

Sin comentarios